15801 chemical lane, huntington beach, ca 92649 phone: (714) 898-0960 fax: (714) 896-0971 name: sheet: date: rhombus p/n: cust p/n: rhombus transformers & magnetic products industries inc. 1 of 1 10/19/00 L-612 www.rhombus-ind.com inductor horizontal mount 1) tested windings in series. pins 1-2 (3,4 shorted) l (1) i dc dcr (1) l l part typ. max. number ( m h ) (amps) ( w) (m h) L-612 28 2.5 .024 4.5 electrical specifications at 25 o c. operating temp. range: -30 o c to +130 o c rated idc based upon 40 o c maximum rise fom 25 o c ambient with 0 arms. single layer windings with spacers specially designed by rhombus industries to provide 3mm creepage and clearance for international safety compliance. operating temperature : these parts are made with materials rated for 130 0 c minimum, and these components can be safely operated up to 130 o c. * 0.880 (22.35) typ. 0.580 (14.73) 0.580 (14.73) 0.270 (6.86) typ. 0.350 (8.90) typ. 0.350 (8.90) typ. 0.180 (4.60) schematic diagram 4 3 1 2 1 3 2 4 leads stripped and tinned to within 0.062" of coil leads diam: 0.0320"
|